The Darmstadt High-Intensity Photon Setup (DHIPS) for photon-scattering
and photodissociation experiments at the superconducting electron linear
accelerator S-DALINAC has been improved. We report on its present
performance. The developments include the installation of a segmented
radiator for an online evaluation of the beam energy and the
construction of a second photon-scattering setup with a Clover detector
to deduce parity assignments. The enhancement of the existing
photon-scattering setup with an additional 100\% HPGe detector and some
minor changes are described as well as the installation of two setups
for photon-induced activation. In addition, we present a comparison of
experimental data to Monte Carlo simulations using the codes Geant 3.21
and GEANT4. (C) 2011 Elsevier B.V. All rights reserved.
%0 Journal Article
%1 ISI:000292442500002
%A Sonnabend, K.
%A Savran, D.
%A Beller, J.
%A Buessing, M. A.
%A Constantinescu, A.
%A Elvers, M.
%A Endres, J.
%A Fritzsche, M.
%A Glorius, J.
%A Hasper, J.
%A Isaak, J.
%A Loeher, B.
%A Muellner, S.
%A Pietralla, N.
%A Romig, C.
%A Sauerwein, A.
%A Schnorrenberger, L.
%A Waelzlein, C.
%A Zilges, A.
%A Zweidinger, M.
%D 2011
%J Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
%K imported myown zilges
%N 1
%P 6-12
%R 10.1016/j.nima.2011.02.107
%T The Darmstadt High-Intensity Photon Setup (DHIPS) at the S-DALINAC
%V 640
%X The Darmstadt High-Intensity Photon Setup (DHIPS) for photon-scattering
and photodissociation experiments at the superconducting electron linear
accelerator S-DALINAC has been improved. We report on its present
performance. The developments include the installation of a segmented
radiator for an online evaluation of the beam energy and the
construction of a second photon-scattering setup with a Clover detector
to deduce parity assignments. The enhancement of the existing
photon-scattering setup with an additional 100\% HPGe detector and some
minor changes are described as well as the installation of two setups
for photon-induced activation. In addition, we present a comparison of
experimental data to Monte Carlo simulations using the codes Geant 3.21
and GEANT4. (C) 2011 Elsevier B.V. All rights reserved.
@article{ISI:000292442500002,
abstract = {The Darmstadt High-Intensity Photon Setup (DHIPS) for photon-scattering
and photodissociation experiments at the superconducting electron linear
accelerator S-DALINAC has been improved. We report on its present
performance. The developments include the installation of a segmented
radiator for an online evaluation of the beam energy and the
construction of a second photon-scattering setup with a Clover detector
to deduce parity assignments. The enhancement of the existing
photon-scattering setup with an additional 100\% HPGe detector and some
minor changes are described as well as the installation of two setups
for photon-induced activation. In addition, we present a comparison of
experimental data to Monte Carlo simulations using the codes Geant 3.21
and GEANT4. (C) 2011 Elsevier B.V. All rights reserved.},
added-at = {2019-11-20T10:09:48.000+0100},
author = {Sonnabend, K. and Savran, D. and Beller, J. and Buessing, M. A. and Constantinescu, A. and Elvers, M. and Endres, J. and Fritzsche, M. and Glorius, J. and Hasper, J. and Isaak, J. and Loeher, B. and Muellner, S. and Pietralla, N. and Romig, C. and Sauerwein, A. and Schnorrenberger, L. and Waelzlein, C. and Zilges, A. and Zweidinger, M.},
biburl = {https://www.bibsonomy.org/bibtex/215f4d19d04d74e09eac556a2aafb491e/ikpcologne},
doi = {10.1016/j.nima.2011.02.107},
eissn = {1872-9576},
interhash = {8b1b55ce036a805f861f39b2937b148e},
intrahash = {15f4d19d04d74e09eac556a2aafb491e},
issn = {0168-9002},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
keywords = {imported myown zilges},
month = {JUN 1},
number = 1,
orcid-numbers = {Glorius, Jan/0000-0003-1785-3221
Pietralla, Norbert/0000-0002-4797-3032},
pages = {6-12},
researcherid-numbers = {Zilges, Andreas/G-9984-2011
Glorius, Jan/AAB-3160-2019
Pietralla, Norbert/L-8465-2017},
timestamp = {2019-11-20T10:09:48.000+0100},
title = {The Darmstadt High-Intensity Photon Setup (DHIPS) at the S-DALINAC},
unique-id = {ISI:000292442500002},
volume = 640,
year = 2011
}