An equation for calculating the spinal-cord depth from a simulator radiograph taken at an oblique angle has been derived. This equation is very useful when the cord cannot easily be identified on a horizontal lateral radiograph as in the case of the lower neck and upper thorax. To use this equation one needs to know the following parameters: the source-Axis-Distance, vertical source-skin-distance, the gantry angle at which the film was taken, and the target-film-distance.
%0 Journal Article
%1 Chen1994
%A Chen, F. S.
%A Watkins, D.
%D 1994
%J Med Dosim
%K Humans; Models, Structural; Radiotherapy Dosage; Spinal Cord, radiation effects/radiography
%N 2
%P 89--91
%T A method for calculating the spinal-cord depth from an oblique simulator radiograph.
%V 19
%X An equation for calculating the spinal-cord depth from a simulator radiograph taken at an oblique angle has been derived. This equation is very useful when the cord cannot easily be identified on a horizontal lateral radiograph as in the case of the lower neck and upper thorax. To use this equation one needs to know the following parameters: the source-Axis-Distance, vertical source-skin-distance, the gantry angle at which the film was taken, and the target-film-distance.
@article{Chen1994,
abstract = {An equation for calculating the spinal-cord depth from a simulator radiograph taken at an oblique angle has been derived. This equation is very useful when the cord cannot easily be identified on a horizontal lateral radiograph as in the case of the lower neck and upper thorax. To use this equation one needs to know the following parameters: the source-Axis-Distance, vertical source-skin-distance, the gantry angle at which the film was taken, and the target-film-distance.},
added-at = {2014-07-19T14:51:09.000+0200},
author = {Chen, F. S. and Watkins, D.},
biburl = {https://www.bibsonomy.org/bibtex/25587dba2b57f997242d1826bb87e7f7b/ar0berts},
groups = {public},
institution = {British Columbia Cancer Agency, Victoria Clinic, Clinical Physics Department, Canada.},
interhash = {5aa9c13e230dde3d66f4aff356751800},
intrahash = {5587dba2b57f997242d1826bb87e7f7b},
journal = {Med Dosim},
keywords = {Humans; Models, Structural; Radiotherapy Dosage; Spinal Cord, radiation effects/radiography},
language = {eng},
medline-pst = {ppublish},
number = 2,
pages = {89--91},
pmid = {7916981},
timestamp = {2014-07-19T14:51:09.000+0200},
title = {A method for calculating the spinal-cord depth from an oblique simulator radiograph.},
username = {ar0berts},
volume = 19,
year = 1994
}