It is shown that the Blaugrund approximation could have led to some imprecise lifetime determinations in the past which used the Doppler-shift attenuation method (DSAM). Comparison with Monte Carlo simulations of the slowing-down process show that there is not an easy way to judge using them on the reliability of old data.
%0 Journal Article
%1 PETKOV201940
%A Petkov, P.
%A Müller-Gatermann, C.
%D 2019
%J Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
%K Blaugrund Carlo DSAM Lifetime Line Monte analysis approximation, determination dewald in measurements, myown shapes simulations,
%P 40 - 46
%R https://doi.org/10.1016/j.nima.2018.10.203
%T On the imprecisions that may be induced when applying the Blaugrund approximation for the analysis of Doppler-shift attenuation lifetime measurements
%U http://www.sciencedirect.com/science/article/pii/S0168900218315274
%V 915
%X It is shown that the Blaugrund approximation could have led to some imprecise lifetime determinations in the past which used the Doppler-shift attenuation method (DSAM). Comparison with Monte Carlo simulations of the slowing-down process show that there is not an easy way to judge using them on the reliability of old data.
@article{PETKOV201940,
abstract = {It is shown that the Blaugrund approximation could have led to some imprecise lifetime determinations in the past which used the Doppler-shift attenuation method (DSAM). Comparison with Monte Carlo simulations of the slowing-down process show that there is not an easy way to judge using them on the reliability of old data.},
added-at = {2019-03-07T17:49:01.000+0100},
author = {Petkov, P. and Müller-Gatermann, C.},
biburl = {https://www.bibsonomy.org/bibtex/28e7353f544f0711d9ce6ba178543d840/ikpcologne},
doi = {https://doi.org/10.1016/j.nima.2018.10.203},
interhash = {f6beab928f02d8b7d5a1220b83563a4f},
intrahash = {8e7353f544f0711d9ce6ba178543d840},
issn = {0168-9002},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
keywords = {Blaugrund Carlo DSAM Lifetime Line Monte analysis approximation, determination dewald in measurements, myown shapes simulations,},
pages = {40 - 46},
timestamp = {2019-03-07T17:49:01.000+0100},
title = {On the imprecisions that may be induced when applying the Blaugrund approximation for the analysis of Doppler-shift attenuation lifetime measurements},
url = {http://www.sciencedirect.com/science/article/pii/S0168900218315274},
volume = 915,
year = 2019
}