S-matrix analysis of coincident measurement of two-electron energy
distribution for double ionization of He in an intense laser field
A. Becker, und F. Faisal. Physical Review Letters, 89 (19):
-(November 2002)607KN Times Cited:42 Cited References Count:35.
Zusammenfassung
Analyses of two mechanisms of double ionization of He in an intense
femtosecond laser pulse are made within the S-matrix theory. Their
contributions are compared with each other and with the recent data
of coincidence measurements for two-electron energy distributions.
It is found that the correlated energy-sharing mechanism reproduces
the data remarkably well and also confirms the so-called "excessive
production" of hot electrons in the process. In contrast, the shakeoff
mechanism is found to fail completely to account for either the strength
or the trend of the data and is therefore ruled out.
%0 Journal Article
%1 Becker2002
%A Becker, A.
%A Faisal, F. H. M.
%D 2002
%J Physical Review Letters
%K ati atoms charged distribution double-ionization gas helium ion ionization mechanism momentum nonsequential production pulses tunneling
%N 19
%P -
%T S-matrix analysis of coincident measurement of two-electron energy
distribution for double ionization of He in an intense laser field
%U /brokenurl#<Go to ISI>://000178790900014
%V 89
%X Analyses of two mechanisms of double ionization of He in an intense
femtosecond laser pulse are made within the S-matrix theory. Their
contributions are compared with each other and with the recent data
of coincidence measurements for two-electron energy distributions.
It is found that the correlated energy-sharing mechanism reproduces
the data remarkably well and also confirms the so-called "excessive
production" of hot electrons in the process. In contrast, the shakeoff
mechanism is found to fail completely to account for either the strength
or the trend of the data and is therefore ruled out.
@article{Becker2002,
abstract = {Analyses of two mechanisms of double ionization of He in an intense
femtosecond laser pulse are made within the S-matrix theory. Their
contributions are compared with each other and with the recent data
of coincidence measurements for two-electron energy distributions.
It is found that the correlated energy-sharing mechanism reproduces
the data remarkably well and also confirms the so-called "excessive
production" of hot electrons in the process. In contrast, the shakeoff
mechanism is found to fail completely to account for either the strength
or the trend of the data and is therefore ruled out.},
added-at = {2011-09-14T10:31:46.000+0200},
author = {Becker, A. and Faisal, F. H. M.},
biburl = {https://www.bibsonomy.org/bibtex/234e99ab9c30d112e369078984e5a90b8/xinguo1},
endnotereftype = {Journal Article},
interhash = {297d2e246fe689cffb9748ca2cc0a8a1},
intrahash = {34e99ab9c30d112e369078984e5a90b8},
issn = {0031-9007},
journal = {Physical Review Letters},
keywords = {ati atoms charged distribution double-ionization gas helium ion ionization mechanism momentum nonsequential production pulses tunneling},
month = {Nov 4},
note = {607KN Times Cited:42 Cited References Count:35},
number = 19,
owner = {xinguo},
pages = {-},
shorttitle = {S-matrix analysis of coincident measurement of two-electron energy
distribution for double ionization of He in an intense laser field},
timestamp = {2011-09-14T10:31:46.000+0200},
title = {S-matrix analysis of coincident measurement of two-electron energy
distribution for double ionization of He in an intense laser field},
url = {/brokenurl#<Go to ISI>://000178790900014},
volume = 89,
year = 2002
}