This paper presents new absolute measurements of the thermal conductivity of aqueous sodium chloride solutions with the transient coated-hot-wire technique. The data cover the range 295-365 K at pressures slightly above the vapor pressures and a concentration range of 0-6 mol kg-1. The instrument is able to measure the thermal conductivity with a precision and reproducibility better than f0.296, and a comparison of the present results with data available in the literature indicates that the accuracy of the present data is better than f0.596. An empirical correlation that reproduces the data within the claimed accuracy is given.
Description
Thermal conductivity of aqueous sodium chloride solutions - Journal of Chemical & Engineering Data (ACS Publications)
%0 Journal Article
%1 Ramires1994
%A Ramires, Maria L. V.
%A de Castro, Carlos A. Nieto
%A Fareleira, Joao M. N. A.
%A Wakeham, William A.
%D 1994
%J Journal of Chemical & Engineering Data
%K water 1994 aqueous NaCl thermal-conductivity
%N 1
%P 186-190
%R 10.1021/je00013a053
%T Thermal conductivity of aqueous sodium chloride solutions
%U http://dx.doi.org/10.1021/je00013a053
%V 39
%X This paper presents new absolute measurements of the thermal conductivity of aqueous sodium chloride solutions with the transient coated-hot-wire technique. The data cover the range 295-365 K at pressures slightly above the vapor pressures and a concentration range of 0-6 mol kg-1. The instrument is able to measure the thermal conductivity with a precision and reproducibility better than f0.296, and a comparison of the present results with data available in the literature indicates that the accuracy of the present data is better than f0.596. An empirical correlation that reproduces the data within the claimed accuracy is given.
@article{Ramires1994,
abstract = {This paper presents new absolute measurements of the thermal conductivity of aqueous sodium chloride solutions with the transient coated-hot-wire technique. The data cover the range 295-365 K at pressures slightly above the vapor pressures and a concentration range of 0-6 mol kg-1. The instrument is able to measure the thermal conductivity with a precision and reproducibility better than f0.296, and a comparison of the present results with data available in the literature indicates that the accuracy of the present data is better than f0.596. An empirical correlation that reproduces the data within the claimed accuracy is given.},
added-at = {2011-01-19T18:07:18.000+0100},
author = {Ramires, Maria L. V. and de Castro, Carlos A. Nieto and Fareleira, Joao M. N. A. and Wakeham, William A.},
biburl = {https://www.bibsonomy.org/bibtex/2d5c65572bf4fb5e4a433a9d59ce5835a/thorade},
description = {Thermal conductivity of aqueous sodium chloride solutions - Journal of Chemical & Engineering Data (ACS Publications)},
doi = {10.1021/je00013a053},
eprint = {http://pubs.acs.org/doi/pdf/10.1021/je00013a053},
interhash = {279ef24013e23f813008c5b84e8938df},
intrahash = {d5c65572bf4fb5e4a433a9d59ce5835a},
journal = {Journal of Chemical \& Engineering Data},
keywords = {water 1994 aqueous NaCl thermal-conductivity},
number = 1,
pages = {186-190},
timestamp = {2011-01-19T18:07:18.000+0100},
title = {Thermal conductivity of aqueous sodium chloride solutions},
url = {http://dx.doi.org/10.1021/je00013a053},
volume = 39,
year = 1994
}