Abstract
In a preclinical research laboratory, using serum samples that have been frozen and thawed repeatedly is sometimes unavoidable when needing to confirm previous results or perform additional analysis. Here we determined the effects of multiple cycles of refrigeration or freezing and thawing of rat serum at 3 temperature conditions for different storage times on clinical chemistry analytes. Serum samples obtained from adult Wistar rats were stored at 2 to 8 �C and -10 to -20 �C for as long as 72 h and at -70 �C for as long as 30 d. At different time points (24, 48, and 72 h for samples stored at 2 to 8 �C or -10 to -20 �C and 1, 7, and 30 d for samples stored at -70 �C), the samples were brought to room temperature, analyzed, and then stored again at the designated temperature. The results obtained after each storage cycle were compared with those obtained from the initial analysis of fresh samples. Of the 18 serum analytes evaluated, 14 were stable without significant changes, even after 3 freeze-thaw cycles at the tested temperature ranges. Results from this study will help researchers working with rat serum to interpret the biochemical data obtained from serum samples that have been frozen and thawed repeatedly.